Pulse Oximeter Description:


In the MedWOW’s catalog, Pulse Oximeter is described as follows:
Oximeter used to calculate the relative amount of oxygenated and deoxygenated hemoglobin by checking light absorbence changes resulting from arterial blood flow pulsations and presenting the results as percent saturation of hemoglobin in arterial blood.
The above ads list companies that sell and / or service Pulse Oximeter.

Pulse Oximeter may also be referred to as:


Blood Gas Monitor, Oxygen | Continues Oxygen Monitor | Multiwavelength Oximeter | Operating Room Monitor | OR Monitor | Oximeter, Ear | Oximeter, Finger | Oximeter, Pulse | Oxygen Monitor | Patient Oxigen Monitor | SpO2 Monitoring

Tips for buying Pulse Oximeter


  • In case of a pulse oximeter that is unable to obtain accurate readings, there should be a clear indication, preferably with the reason.
  • Multiwavelength oximeters intended for transport outside the facility should operate at least eight hours without charging.
  • Multiwavelength oximeters intended for transport within the facility should operate at least four hours without charging.
  • Finger oximeter units usually operate on AC power, and many have battery backup as well. The unit should switch automatically to battery power if line power fails.
  • Audible and visual alarms should alert for high and low SpO2/pulse rate, sensor off, and low battery.
  • In addition to SpO2 and pulse rate, the pulse oximeter should also display pulse strength and low battery.
  • The pulse oximeter probes should provide accurate measurements, while tolerating probe movement caused by the patients or clinicians.
  • The multiwavelength oximeter should display at least 70% to 100% SpO2 values with an accuracy of
  • Most pulse oximeters can interface with printers, recorders, computers, or multiparameter monitoring systems. It is important to make sure that the purchased unit is compatible with existing equipment.
  • Pulse Oximeter units can either be stand-alone or a module in a larger patient monitor.